Front Panel Schematic
Figure 3-4. Front Panel Schematic
IMPORTANT:
Disabling the High Power button violates IEC 60204-1. We
strongly recommend that you not alter the use of the High Power button.
3.5 Air Lines and Signal Wiring
The robot is equipped with seven air lines. Six lines, from AIR1 input, are controlled by the
three internal solenoid valves. One line, from AIR2 input, is connected directly to AIR2 on the
second arm. There are ten user electric lines. See the following figures and tables.