background image

Software components only. This package doesn’t include SYSMAC Gateway as communications drivers. 

Supported OS: Microsoft Windows Vista, XP, 2000, and 2003 Server 

1

 One license is required per computer. 

2

 Only functions provided by Compolet V2 as ActiveX controls are supported for Visual Basic version 5 or 6.

Supported OS: Microsoft Windows Vista, XP, 2000, and 2003 Server 

1

 One license is required per computer.

SYSMAC Gateway

 (Communications Middleware)

CX-Compolet

Correspondence between Main PLC Models and Connected Networks

SYSMAC Gateway

CX-Compolet

CS1

CP1

 

C200HX/HG/HE, CQM1H

 CPM1/CPM2

CVM1/CV

CompoWay/F Slaves, such as Temperature Controllers

 
 

WS02-CPLC1

WS02-SGWC1S

WS02-SGWC1-L10

WS02-SGWC1

WS02-CPLC1-L3

WS02-CPLC1-L5

WS02-CPLC1-L10

WS02-CPLC2

3 additional licenses (This product provides only additional licenses. The software must be purchased in advance.)

5 additional licenses (This product provides only additional licenses. The software must be purchased in advance.) 

10 additional licenses (This product provides only additional licenses. The software must be purchased in advance.)

Software development kit for creating communications programs using SYSMAC Gateway.
Development languages: C, C++, Visual Basic.NET, Visual C#.NET 

Model 

Specification

Product name

Standards 

Ordering Information


Series

PLC

A separate Communications Unit is required. 

Specification using tag names is not possible.

CJ2 with EtherNet/IP functionality

CJ1

Personal computer

RS-232C

Ethernet
(FINS)

Peripheral Bus

FINS

FINS

EtherNet/IP

USB

Controller Link

Ethernet (LAN)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

Yes

Yes

Yes

Yes

No

No

Yes

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Correspondence between FA Communications Software and Connected Networks

FA Communications Software

Personal Computer Boards 

⋅ 

SYSMAC Gateway

⋅ 

CX-Compolet

Communications

Message 
communications

Data link 
communications

Communications 

method

SYSMAC 
Board

CS1 Board

FINS communications

FINS communications

Communications middleware for personal computers running Windows. Supports CIP communica-
tions and tag data links (EtherNet/IP) in addition to FinsGateway functions.
Supported communications: RS-232C, USB, Controller Link, SYSMAC LINK, Ethernet, EtherNet/IP 

10 additional licenses (This product provides only additional licenses.)

Standards 

Model 

SYSMAC Gateway SDK

Specification

Product name

Software components that can make it easy to create programs for communications between a 
computer and controllers. This packaged product bundles SYSMAC Gateway.
Development environment: Visual Studio.NET2003/.NET2005/.NET2008
Development languages: Visual Basic .NET, Visual C#.NET, Visual Basic Ver. 5/6

2

Supported communications: Equal to SYSMAC Gateway. 

SYSWAY 

(Host Link C 

Mode)

SYSWAY-

CV (Host 

Link FINS)

CompoWay/F 

(master at personal 

computer) 

Yes (Peripheral 

Bus – CS/CJ)

Yes (Peripheral 

Bus – CS/CJ)

Yes (Peripheral 

Bus – CS/CJ)

Yes (Peripheral 

Bus – CS/CJ)

Yes (Peripheral 

Bus – C)

Yes (Peripheral 

Bus – C)

Yes (Peripheral 

Bus – CV)

No

Yes

2

No

No

Yes

No

No

No

No

Yes

1

Yes

1

Yes

1

Yes

1

No

Yes

1

No

Yes

1

 (CP1H only)

No

No

No

No

No

Yes (Specification 

using tag names is 

possible.)

Yes

1, 

2

Yes

1, 

2

Yes

1

 (CP1H only)

No

No

Yes

1

No

Yes

Yes

1

Yes (Communications Units 

are not required for CJ1M 

PLCs with Ethernet 

functionality.)

1

CS1 Bus 
Interface 
Board

Note: Do not use this document to operate the Unit.

This catalog mainly provides information that is necessary for selecting suitable models, and does 
not contain precautions for correct use. Always read the precautions and other required information 
provided in product operation manuals before using the product. 

The application examples provided in this catalog are for reference only. Check functions and 
safety of the equipment before use.
Never use the products for any application requiring special safety requirements, such as nuclear 
energy control systems, railroad systems, aviation systems, medical equipment, amusement 
machines, vehicles, safety equipment, or other application involving serious risk to life or property, 
without ensuring that the system as a whole has been designed to address the risks, and that the 
OMRON products are properly rated and installed for the intended use within the overall equipment 
or system. 

Authorized Distributor:

In the interest of product improvement, 
specifications are subject to change without notice.

Cat. No. V302-E1-02

Printed in Japan

0209 (0109)

OMRON Corporation

Industrial Automation Company

Regional Headquarters

OMRON EUROPE B.V.

Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ELECTRONICS LLC

One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 
200 Yin Cheng Zhong Road, 
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON Industrial Automation Global: 

www.ia.omron.com

Control Devices Division H.Q.
PLC Division

Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81) 75-344-7084/Fax: (81) 75-344-7149

 © OMRON Corporation 2009  All Rights Reserved.