14
Connecting to a PC
Section 2-2
1,2,3...
1.
Select
Programs/FinsGateway/FinsGateway Settings
from the
Start
Menu.
2.
Select the desired communications driver under
Driver
under
Network
on
the
Basic
Tab Page, click
Properties
, and make the required settings
(COM port used, communications protocol (see note), communications
conditions, etc.).
Note
For example, select
SYSWAY-CV
to connect via Host Link
(SYSWAY-CV).
3.
Select the desired communications driver (service) under
Services
on the
Basic
Tab Page, and click the
Start
Button.
2-2-1
Connecting via Host Link (SYSWAY-CV)
To connect via Host Link, use FinsGateway Version 3’s Serial Unit driver. Use
Host Link (SYSWAY-CV) to connect to the PC’s peripheral port or RS-232C
port.
Connection Method
Note
Use the CS1W-CN118 to connect to the peripheral port of the CPU Unit using
one of the RS-232C cables shown on the right (XW2Z-
@@@@
-
@@
) in the way
shown below.
Note
With CS/CJ-series PCs, it is also possible to connect to ports on Serial Com-
munications Units/Boards. In this case, connection can be made by Host Link
only.
NEC
PC-9801BX
NEC
PC-9801BX
Computer
IBM PC/AT
or
compatible
Connection to peripheral port
Connection to RS-232C port
9 pin, male
9 pin,
male
9 pin,
female
CS1W-CN118 (0.1 m) (See note.)
CS1W-CN226 (2.0 m)
CS1W-CN626 (6.0 m)
Peripheral port
10 pin, female
CS1W-CN118 (See note.)
CS1W-CN226
CS1W-CN626
9 pin, female
10 pin
RS-232C port
9 pin, female
9 pin,
male
XW2Z-200S-CV/200S-V (2.0 m)
XW2Z-500S-CV/500S-V (5.0 m)
9 pin, female
XW2Z-200S-CV/200S-V
XW2Z-500S-CV/500S-V
9 pin, male
NEC
PC-9801
BX
CS1W-CN118
RS-232C cable
Peripheral port