58
Editing Speed Settings
Section 4-5
4-5
Editing Speed Settings
4-5-1
Speed Setting Editing Screen
On the project tree, either double-click
Edit Speeds
, or select it and press the
Enter
Key.
Example: The following will be displayed as the 4-axis NC Unit speed Setting
Editing Screen.
4-5-2
Editing Speed Settings
The speed setting range is from 00000000 to 000F4240 Hex (0 to 1,000,000)
(pps). If the pulse rate is set to a value other than
1
, the value displayed will
change to specified set value times the pulse rate. Refer to
4-2-2 Editing Set-
tings
for editing methods.
Note
The speeds set above can be set as interpolation speeds. Make sure, how-
ever, that the maximum speed of individual axes does not exceed 500,000
(pps) or the maximum speed set in the parameter settings.
Example: The following will be displayed as the Speed Setting Editing Screen.
To Clear to Default
Settings
Use the following procedure to clear specific settings to their default values.
(Refer to
4-2-4 Clearing Settings
for details.)
1,2,3...
1.
On the speed Setting Editing Screen, select the settings to be cleared to
their default values, or designate the range by clicking and dragging.
2.
Select
Edit/Clear
To Copy Axes
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes. (Refer to
4-2-5 Copying
Axis Settings
for details.)
1,2,3...
1.
Select
Edit/Copy Axis
.
2.
Under
From
and
To
, select the axes to be copied from and to respectively.
3.
Click the OK Button.