61
Editing Zone Settings
Section 4-8
4-8
Editing Zone Settings
4-8-1
Zone Setting Screen
On the project tree, either double-click
Edit Zone
, or select it and press the
Enter
Key.
Example: The following will be displayed as the 4-axis NC Unit Zone Setting
Editing Screen.
4-8-2
Editing Zone Settings
The zone setting range is as follows.
Pulse: C0000001 to 3FFFFFFF Hex (
±
1,073,741,823) (pulse)
mm or inches: Above set value
×
pulse rate
Example: The following will be displayed as the Zone Setting Editing Screen
(hexadecimal display shown).
To Clear to Default
Settings
Use the following procedure to clear specific setting to their default values.
(Refer to
4-2-4 Clearing Settings
for details.)
1,2,3...
1.
On the zone Setting Editing Screen, select the settings to be cleared to
their default values, or designate the range by clicking and dragging.
2.
Select
Edit/Clear
To Copy Axes
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes. (Refer to
4-2-5 Copying
Axis Settings
for details.)
1,2,3...
1.
Select
Edit/Copy Axis
.
2.
Under
From
and
To
, select the axes to be copied from and to respectively.
3.
Click the
OK