2
Measurement
150
Scan Edge Width
FZ3 Processing Items List Manual
Setting item
Set value
[factory default]
Description
Display area No.
[0] to 99
This item uses the scan region of which edge
profile is displayed.
Enabled
●
[Checked]
●
Unchecked
Specify enable/disable of the divided area.When
disabled (unchecked) is specified, measurement is
not performed.
●
[Forward
area]
●
Reverse
area
Forward area: The edge is searched from the start
point of the area toward the end point.
Reverse area: The edge is searched from the end
point of the area toward the start point.
3.
Set the value of each item in the "Measurement" area.
For color cameras:
Setting item
Set value
[factory default]
Description
Edge level
●
Position (%) for width
of a color
0 to 100 [50]
●
Value of color
0 to 442 [20]
Select a color difference level with which the edge is
detected.
Reference:
See "User's Manual", "Edge level" (p.304)
Edge color
level
0 to 442
[100]
This emphasis level can be specified only if the edge
color to detect is specified.
For monochrome cameras:
Acesst 1.0 6251194