2
Measurement
FZ3 Processing Items List Manual
Fine Matching
227
Note
●
Specify [Boundary inspection] in [Model register] and [Inspection] in [Measurement] according to the inspection
objectives.
Model Registration (Fine Matching)
Register a fine image as the model.By matching this model with input images, unmatched parts will be
detected as defects during inspection.
Note
Ranges that can be registered as models
●
The two pixels on the edge of the screen are not registered as a model.
●
The registering range will be lower if the images of measurement object are set with Filtering.When you set the image
reading range using a camera with the partial scanning function, the range is also limited. Reference:
Filtering (p.294)
●
When figures are drawn overlapping, the settings for objects set up afterward are enabled.
Reference:
See "User's Manual", " Setting Figures " (p.319)
1.
In the Item Tab area, tap [Model register].
When setting a new model, you do not have to tap [Model register].
2.
Use the drawing tools to specify the model registration range.
3.
In the figure setting area, tap [OK].
The model is registered.
Changing Model Parameters
The range can be changed as needed to address unstable measurement results.Normally, the factory
default value will be used.
After changing a setting, check whether measurement can be done properly by performing an actual
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...