2
Measurement
256
Model Dictionary
FZ3 Processing Items List Manual
6.
To register two or more models, repeat the Steps Reference:
3(p.255) to Reference:
5(p.255) .
Changing Model Parameters
Model parameter values can be changed as needed to address unstable measurement results or to
increase the processing speed.Normally, the factory default value will be used.
After changing a setting, check whether measurement can be done properly by performing an actual
measurement.
Important
●
After model parameters are modified, re-register all models.
1.
In the "Model parameter" area, specify a value for each item.
Setting item
Set value
[Factory default]
Description
Rotation
●
Checked
●
[Unchecked] When the measurement object rotates, place a
check at "Rotation" and set the Angle range during
a search.The normal direction is clockwise.
Angle range
-45 to 45
[0]
Smart mode
●
[Checked]
●
Unchecked
Checking the "Smart mode" option enables a
high-speed rotation search.The stability may be
lowered when the model shape aspect ratio is large
or when the NOT mask is used.
Acesst 1.0 6251194