4
Support
measurement
FZ3 Processing Items List Manual
Iris
395
The rectangle covering the entire screen is set. Adjust the size and position of the rectangle.
4.
Tap [OK].
The range to adjust is registered.
Output Parameter (Iris)
Specifies whether or not the judgement results of this processing unit is reflected in the scene overall
judgement.
1.
Tap [Output parameter] in the item tab area.
2.
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Setting value
[Factory default]
Description
Reflect to overall
judgement
●
[ON]
●
OFF
Enables choosing whether or not the judgement results of this
processing unit is reflected in the scene overall judgement.
Key Points for Test Measurement and Adjustment (Iris)
Displayed items
Description
Judge
Judgement result
In range
Percentage inside the valid brightness range
R average
R average in the region
G average
G average in the region
B average
B average in the region