5
Branch
406
DI Branch
FZ3 Processing Items List Manual
2.
Tap the DI input from the input signal list for which the branch destination is to be set up.
3.
At "Destination unit", tap [
] and set the destination unit.
Important
●
In order to avoid measurement processing looping, for the branch destination, set a processing unit
number that is after the [DI Branch].
●
Make sure to set "End" at the last branch destination to indicate the end of the branch.
Reference:
Measurement Completion (p.403)
●
If the operation mode (FZ3-9
/H9
only) is set to [Multi-line random-trigger mode], DI inputs are
handled differently as follows.
Line 0: Conform to the statuses of DI0 and 1 inputs.
Line 1: Conform to the statuses of DI2 and 3 inputs.
4.
Repeat the steps Reference:
2(p.406) to Reference:
3(p.406) and set the destination units for other input signals.
Note
●
Up to 32 (0 to 31) branch destinations can be set.
●
The controller references the DI signal when the [DI Branch] measurement is executed.
5.
Tap [OK].
The settings are finalized.
Measurement Results for Which Output Is Possible (DI Branch)
The following values can be output using processing items related to results output.It is also possible to
reference measurement values from expressions and other processing units.
Acesst 1.0 6251194
Summary of Contents for XPECTIA FZ3
Page 11: ...FZ3 Processing Items List Manual 9 Index 435 ...
Page 39: ...1 Input image FZ3 Processing Items List Manual Camera Image Input HDR 37 ...
Page 41: ...1 Input image FZ3 Processing Items List Manual Camera Switching 39 ...
Page 398: ...4 Support measurement 396 Iris FZ3 Processing Items List Manual ...
Page 410: ...5 Branch 408 DI Branch FZ3 Processing Items List Manual ...