Safety Precautions
Do not use the Connectors in an atmosphere or environment that
exceeds the specifications.
Connector Connection and Disconnection
•
When connecting or disconnecting Connectors, be sure to hold the
Connectors by hand.
•
Do not hold the cable when disconnecting Connectors.
•
When mating Connectors, be sure to insert the plug all the way to
the back of the socket before attempting to lock the Connectors.
•
Do not use tools of any sort to mate the Connectors. Always use
your hands. Pliers or other tools may damage the Connectors.
•
When mating the Connectors to XS2 or other M12 Connectors,
tighten the lock by hand to a torque of 0.39 to 0.49 N
⋅
m.
Wiring
•
Always confirm wiring diagrams before wiring sensors, limit
switches, or other devices.
•
Lay the cables so that external force is not applied to the
Connectors. Otherwise, the degree of protection (IP67) may not be
achieved.
Degree of Protection
•
The degree of protection of Connectors (IP67) is not for a fully
watertight structure. Do not the Connectors underwater.
•
Do not step on or place any objects on the Connectors. Doing so
may damage the Connectors.
General Precautions
•
Do not pull excessively on the Connectors or cables. Do not install
the Connectors or cables in any way that would place a load
directly on the mating section or cable connections. Doing so can
damage the Connectors or break the wires inside the cables.
•
Install the Connectors and cables where they will not be stepped
on to prevent the wires inside the cables from being broken and to
prevent the Connectors from being damaged. If the Connectors or
cables must be installed where they might be stepped on, protect
them with covers.
•
Refer to the specifications for your cables before bending the
cables and do not bend them past their minimum bending radius.
•
If sensors or switches are not attached during installation, protect
the mating surface of the Connector with a XS2Z-22 Waterproof
Cover of XS2Z-14/15 Dust Cover.