XW5T
5
Ratings and Performance
Ratings
Feed Through Terminal blocks Standard terminals
*1.
For the recommended applicable wire ranges, refer to page 17 for solid and stranded wires, and to page 19 for ferrules.
*2.
You can also use ferrules for 1.0 to 1.5 mm
2
wires if you use ferrules without insulation sleeve. Refer to page 19 for details.
*3.
Do not apply more than the rated current to the terminal block.
Model
XW5T-P1.5-1.1-1 (BL)
XW5T-P2.5-1.1-1 (BL)
XW5T-P4.0-1.1-1 (BL)
Appearance and internal
wiring
1 tier, 1:1
1 tier, 1:1
1 tier, 1:1
Appli
cabl
e wi
re
s
izes*
1
Stranded wire
0.08 mm
2
to 1.5 mm
2
0.14 mm
2
to 2.5 mm
2
0.2 mm
2
to 4.0 mm
2
Solid wire
0.14 mm
2
to 1.5 mm
2
0.14 mm
2
to 4.0 mm
2
0.2 mm
2
to 6.0 mm
2
Stranded wire with
ferrule with Plastic
sleeve
0.14 mm
2
to 0.75 mm
2
(1.5 mm
2
) *2
0.14 mm
2
to 2.5 mm
2
0.25 mm
2
to 4.0 mm
2
Dimensions
3.5 × 45 × 30.5
5.2 × 48.8 × 35.3
6.2 × 56.1 × 35.3
Rated voltage
500 V
800 V
Rated current *3
17.5 A
24 A
32 A
IEC rated voltage
500 V
800 V
800 V
IEC rated current *3
17.5 A/1.5 mm
2
24 A/2.5 mm
2
32 A/4.0 mm
2
Usage Group (UG)
B, C
D
B, C
UL rated voltage
300 V
51-150 V 151-300 V
301-600 V
600 V
UL rated current *3
15 A/AWG14
(SOL)
10 A/AWG16
15 A/AWG14
(SOL)
10 A/AWG16
10 A/
AWG16
5 A/
AWG16-20
20 A/AWG12 (SOL), 15 A/AWG14
30 A/AWG10 (SOL), 20 A/AWG12
Dielectric strength
1,890 VAC for 1 min
(leakage current: 1 mA max.)
2,000 VAC for 1 min
(leakage current: 1 mA max.)
2,000 VAC for 1 min
(leakage current: 1 mA max.)
End Cover
XW5E-P1.5-1.1-1
XW5E-P2.5-1.1-1
XW5E-P4.0-1.1-1
Special tool
XW4Z-00B
XW4Z-00B
XW4Z-00B
Applicable nameplates
XW5Z-P1.5LB
@
or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
XW5Z-P2.5LB
@
or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
XW5Z-P4.0LB
@
or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
Applicable Short Bars
XW5S-P1.5-
@
(
@
: Poles = 2, 3, 4, 5 or 10)
XW5S-P2.5-
@
(
@
: Poles = 2, 3, 4, 5 or 10)
XW5S-P4.0-
@
(
@
: Poles = 2, 3, 4, 5 or 10)