1

Common Terminal Blocks with Visible Indicators

XW6T

Downsize Control Panels and Save Work 
with Common Terminal Blocks with 
Visible Indicators

• Indicators make wiring completion simply visible.

Proper wiring without skillful operators.

• Simply check the indicators for wiring maintenance,

helping reduce maintenance works.

• Short Bars enable pre-connected common wiring. No

troublesome crossover wiring required.

• The best-in-class slim models available to help downsize

control panels.

• Wiring system interface with Push-In Plus technology enables

no loosening of wiring, providing a maintenance-free operation.

Model Number Legend

Model Reference

Use this legend when determining the product specifications from the model number. Select models from 

Ordering Information

 for orders.

Part Names and Configuration

Terminal Block

Basic Configuration

For the most recent information on models that have been 
certified for safety standards, refer to your OMRON 
website.

Refer to 

Safety Precautions

 on page 11.

XW6T - COM 

@@ 

@@@@

(1)

(2)

(3)

(2) Number of Pins

8: 8 pins

12: 12 pins
16: 16 pins
20: 20 pins
40: 40 pins

(1) Maximum Applicable 

Stranded Wire

1.5: 1.5 mm

2

2.5: 2.5 mm

2

(3) Color of Short Bars

RD: Red
BL: Blue
YL: Yellow

Terminal (insertion) hole
Release hole (to release wire)

Label attachment section

Indicator 
(Wire insertion state indication part)

Insertion hole for Short Bars
• Insert the tester pins here to

perform a continuity check.

Note:

Do not insert more than one wire into 

each terminal (insertion) hole.

Name

Description

Common 
Terminal Block

Five types of 8/12/16/20/40 pins are available.

End Cover

This part is required to prevent electrical shock. 
Attached on the end surface (metal exposure part) of the 
last terminal block.

End Brackets

This part is available as an accessory. End blocks must be 
attached on the both ends to hold terminal block in place.

Nameplate or 
Labels

This part is available as an accessory.
Select the most suitable one for your needs.
You can also use commercially available nameplates that 
are 9.5 mm wide and 0.5 mm thick.

Short Bars

All pins are shorted.

Indicator

Turns in green when the connection is completed.

Common Terminal Block

End Cover

Order separately

Nameplate or Labels

Short Bars

Indicator 
(Wire insertion state 
indication part)

End Brackets

Summary of Contents for XW6T Series

Page 1: ...ns 8 8 pins 12 12 pins 16 16 pins 20 20 pins 40 40 pins 1 Maximum Applicable Stranded Wire 1 5 1 5 mm2 2 5 2 5 mm2 3 Color of Short Bars RD Red BL Blue YL Yellow Terminal insertion hole Release hole t...

Page 2: ...T COM1 5X12RD Blue XW6T COM1 5X12BL Yellow XW6T COM1 5X12YL 16 Red Approx 29 XW6T COM1 5X16RD Blue XW6T COM1 5X16BL Yellow XW6T COM1 5X16YL 20 Red Approx 36 XW6T COM1 5X20RD Blue XW6T COM1 5X20BL Yell...

Page 3: ...cks Number of poles Covering color Model Application XW6T COM1 5X 2 Red RD Blue BL Yellow YL XW5S P1 5 2 Used for crossover wiring between Terminal Blocks 3 XW5S P1 5 3 4 XW5S P1 5 4 5 XW5S P1 5 5 10...

Page 4: ...8 16 pins 23 0 20 pins 28 2 40 pins 54 2 IEC rated voltage 500 V 800 V IEC rated current 17 5 A 1 5 mm2 24 A 2 5 mm2 Usage Group UG B C D B C UL rated voltage 300 V 51 to 150 V 151 to 300 V 301 to 60...

Page 5: ...l Number of pins Dimensions XW6T COM1 5X8 8 pins 9 2 XW6T COM1 5X12 12 pins 12 7 XW6T COM1 5X16 16 pins 16 2 XW6T COM1 5X20 20 pins 19 7 XW6T COM1 5X40 40 pins 37 2 A 30 1 82 6 36 1 XW6T COM2 5X Dimen...

Page 6: ...XW5S P1 5 2 3 5 XW5S P1 5 3 7 0 XW5S P1 5 4 10 5 XW5S P1 5 5 14 0 XW5S P1 5 10 31 5 XW5S P2 5 Model P mm XW5S P2 5 2 5 2 XW5S P2 5 3 10 4 XW5S P2 5 4 15 6 XW5S P2 5 5 20 8 XW5S P2 5 10 46 8 5 2 23 3 1...

Page 7: ...mount them so that the conductive parts of the adjacent Terminal Blocks are facing in the same direction If they face in different directions short circuit may occur between adjacent Terminal Blocks D...

Page 8: ...e release hole Checking Connections When you complete wiring an indicator for the wire insertion state turns to green To prevent short circuits insert the stripped part of a stranded or solid wire or...

Page 9: ...E 0 75 8N GY 10 12 AI 0 75 10 H0 75 16 FE 0 75 10N GY Recommended crimp tools CRIMPFOX6 CRIMPFOX6T F CRIMPFOX10S PZ6 roto Variocrimp4 Applicable wire Ferrule Conductor length mm Stripping length mm Fe...

Page 10: ...it up from the Terminal Block 1 operate the screwdriver so that it catches the hook 2 and then remove the Terminal Block with the divided state 3 However do not apply excessive force to the Terminal...

Page 11: ...nnected to each other Side surface Labels 1 Remove the Labels one at a time 2 Insert them on the sides of the Terminal Blocks Note 1 Different models of Labels are used for the top and side surfaces 2...

Page 12: ...TERS Chicago IL USA 847 843 7900 800 556 6766 automation omron com Controllers I O Machine Automation Controllers MAC Motion Controllers Programmable Logic Controllers PLC Temperature Controllers Remo...