4
Edit
4-63
■
EtherNet/IP IP address
‹
EIPADD
›
This parameter sets the IP address. When this parameter is initialized, "0.0.0.0" is set.
■
EtherNet/IP subnet mask
‹
EIPSUB
›
This parameter sets the subnet mask. When this parameter is initialized, "0.0.0.0" is set.
■
EtherNet/IP default gateway
‹
EIPDEF
›
This parameter sets the gateway. When this parameter is initialized, "0.0.0.0" is set.
■
EtherNet/IP DHCP enable
‹
EIPDHCP
›
This parameter sets the DHCP function VALID or INVALID.
Set this parameter to "VALID" when assigning the IP address, etc. from the host unit. When this parameter is initialized,
"0: INVALID" is set.
Setting
Meaning
0
INVALID
1
VALID
* When the DHCP function is valid, the setting value of IP address, subnet mask and gateway is "0.0.0.0".
■
SIOW extension
‹
SIOWEXT
›
This parameter sets the SIOW extension enabled or disabled.
When this parameter is enabled, the word IO area in the field network is exteded to use SIW(24)-(127) and SOW(24)-
(127) as the general IO ports.
Only EtherNet/IP and PROFINET support this function.
When this parameter is initialized, "0: INVALID" is set.
NOTE
•
To use the real time output function, enable this parameter and extend the word IO area.
•
For details about the SIOW extension function, refer to the relevant field network manual.
CAUTION
• When using the unsupported field network, this parameter is not shown on SCARA-YRCX Studio.
• Even if you use the field network that supports the SIOW extension, the communication cannot be established
unless you use the setting file that supports SIOW extension and set PLC correctly.
Setting
Meaning
0
INVALID
1
VALID
Summary of Contents for YRCX Series
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 23 5 7 21 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 20: ......
Page 28: ......
Page 164: ......
Page 166: ......
Page 178: ......
Page 186: ......
Page 264: ......
Page 265: ......
Page 266: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...