A
Troubleshooting
A-70
26.396 : Gripper cannot get error
Code
: &H001A &H018C
Meaning/Cause
Obtaining an error generated by the gripper itself failed.
Action
Contact your distributor.
26.397 : Gripper disconnected
Code
: &H001A &H018D
Meaning/Cause
a. The specified gripper is not connected.
b. Generation is incomplete for the specified gripper.
Action
a. Connect the gripper.
b. Make gripper settings.
26.398 : Illegal gripper no
Code
: &H001A &H018E
Meaning/Cause
A gripper number outside the range from 1 to 4 was specified.
Action
Specify a gripper number between 1 and 4.
26.399 : Gripper timeout error
Code
: &H001A &H018F
Meaning/Cause
Execution of a command sent to the gripper control board ended in timeout.
Action
Contact your distributor.
26.435 : Gripper origin incomplete
Code
: &H001A &H01B3
Meaning/Cause
Return-to-origin has not been performed.
Action
Perform return-to-origin so that the gripper is in the return-to-origin complete status.
26.604 : Gripper 24V power supply voltage low
Code
: &H001A &H025C
Meaning/Cause
The 24 V DC power supply voltage is less than 80% of the rated value.
Action
Check the power supply capacity, and if it is insufficient, adjust the power supply voltage to be
within the rated range.
26.608 : Gripper 24V power off
Code
: &H001A &H0260
Meaning/Cause
a. The 24 V DC power supply is not wired.
b. The 24 V DC power supply is not being provided.
c. The 24 V DC power supply cable is disconnected.
Action
a. Check the wiring of the 24 V DC power supply.
b. Check the 24 V DC power supply.
c. Check the 24 V DC power supply cable.
Summary of Contents for YRCX Series
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 23 5 7 21 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 20: ......
Page 28: ......
Page 164: ......
Page 166: ......
Page 178: ......
Page 186: ......
Page 264: ......
Page 265: ......
Page 266: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...