7.5 PRM skip
This function sets skipping the undefined data of parameter files to load the controller (parameters that the
controller is not corresponded) or not.
Undefined data in the file will be skipped when the parameter files are loaded with this function “VALID”.
This function is not included in the parameter file.
CAUTION
Spelling mistakes in the parameter file are not detected when this function is “VALID”. Do not set this to “VALID”
except the case that it is necessary to load the parameters from later version controller into the earlier one.
NOTE
New parameters may added as the controller software upgrading. “10.214: Undefined parameter found” alarm
will occur when the later version parameter file including such new parameters is load to the controller with
earlier version.
Step 1
Press the F3 key (PRM SKIP) on the
"PAREMETER>CONT" screen.
"PARAMETER>CONT" screen
Step 1
Step 2
Input the value.
"PRM SKIP" screen
Step 2
Input "1" and press the ENTER key to enable
"Do not load undefined parameters". To
disable, input "0" and press the ENTER key.