A
Troubleshooting
A-62
17.996 : Mode error 1
Code
: &H0011 &H03E4
Meaning/Cause
Error occurred in software for driver unit.
Action
Contact your distributor.
17.997 : Mode error 2
Code
: &H0011 &H03E5
Meaning/Cause
Error occurred in software for driver unit.
Action
Contact your distributor.
17.999 : Undefined
Code
: &H0011 &H03E7
Meaning/Cause
Undefined system error.
Action
Contact your distributor.
[19] Alarm related to the YC-Link/E
19.400 : YC/E slave connecting retry
Code
: &H0013 &H0190
Meaning/Cause
The YC-Link/E slave is retrying the connection establishment with the master.
Action
Please wait while retrying the connection.
19.500 : YC/E master port open fail
Code
: &H0013 &H01F4
Meaning/Cause
The communication port of the YC-Link/E master board does not open within a certain period of
time (about 20 seconds).
Action
• Check that the master and slave are connected with the cables.
• Check the slave power is turned on.
19.501 : YC/E communicate initialize fail
Code
: &H0013 &H01F5
Meaning/Cause
The communication failed in the initialization process of the YC-Link/E connection.
Action
• Restart the controller.
• Take noise preventive measures.
• Replace the slave option board.
19.502 : YC/E slave port wrong
Code
: &H0013 &H01F6
Meaning/Cause
The IN port and OUT port of the YC-Link/E slave are used incorrectly.
Action
• Check the connection.
• Reconnect the cable into the correct port.
Summary of Contents for YRCX Series
Page 1: ...7 6HULHV DW 1R 1 5 5RERW RQWUROOHU 23 5 7 21 0 18 6 5 5RERWV 5 6HULHV...
Page 2: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 20: ......
Page 28: ......
Page 164: ......
Page 166: ......
Page 178: ......
Page 186: ......
Page 264: ......
Page 265: ......
Page 266: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...