4-2
Section
Key Settings
39
4-2-2
Selecting the Discrimination Outputs (
oUt
)
There are three methods to discriminate and output measure-
ment data. Select the best method for the application.
1
HIGH/LOW Output Mode (
hĆl1
)
Measured value
x
HIGH threshold: HIGH output ON
Measured value
y
LOW threshold: LOW output ON
2
PASS/NG Output Mode (
pass
)
LOW threshold < Measured value < HIGH threshold:
PASS output ON
Measured value
x
LOW threshold or
Measured value
y
HIGH threshold:
NG output ON
3
HIGH/LOW Inverted Output Mode (
hĆl2
)
Measured value
y
HIGH threshold: HIGH output ON
Measured value
x
LOW threshold: LOW output ON
HIGH threshold
LOW threshold
Measured value
HIGH/LOW
output mode
Discrimina-
tion output
Indicator
PASS/NG
output mode
Discrimina-
tion output
Indicator
HIGH/LOW
inverted out-
put mode
Discrimina-
tion output
Indicator
ON
OFF
Procedure
1
Set the operating mode selector to RUN.
2
Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.