SECTION 3
Setting Measurement Conditions (Expert Menu)
Selecting Hold Conditions for Measurement Values
The hold function allows holding (maintaining) an arbitrary value, such as the maximum or minimum
values, among the measurement values obtained from the start to the end of the measurement, and
outputting the value after the measurement is completed.
Example 1: Holding the peak value (used in combination with hold output)
How to set the timing to trigger hold measurement
p.118
Example 2: Holding the peak value for every three measurements (used in combination with the logging
function)
How to set the logging function
p.126
It is possible to hold the following five types of values. The item to be held can be specified for each
output (OUT0 to 7).
Hold the peak value
Start of measurement
Measurement
value
End of measurement
Output the held value
at the end of the measurement.
Accumulate and output
the held value.
Accumulate and output
the held value.
Accumulate and output
the held value.
Measurement
Measurement
value
Peak value
Peak value
Peak value
1
2
3
1
2
3
1
1
2
3
Item
Meaning
Sampling
The value at the start of the measurement is held.
Peak
The highest value measured during the measurement is held.
Bottom
The lowest value measured during the measurement is held.
Peak-Peak
The difference between the highest and lowest values measured during
the measurement is held.
Average
The average between the highest and lowest values measured during
the measurement is held.
None
Hold measurement is not performed.