229
Z550
Operation Manual
S
E
CT
IO
N 6
Tim
ing Ch
arts
SECTION 6
Communication with External Devices
Timing Chart 8
Measurement is performed according to the TRG signal of the terminal block, and measurement
values are accumulated and output according to the specified logging conditions. When the hold
conditions are specified, the corresponding values are held, accumulated, and then output.
Assuming the sampling interval is set to three samples
*1 ALL-PASS and ERROR outputs are always output at the timing when "no hold" is set.
*2 The GATE output does not function at logging.
Measurement mode
Hold&Logging
Trigger measurement
(External)
Logging
Image acquisition
Calculation
processing
Terminal block output
Analog output
(OUT for which hold is set)
PROFILE data
(sent by Controller)
Terminal block output (*1)
Analog output
(OUT for which no hold is set)
TRG
of terminal block
OFF
ON
GATE output
(*2)
OFF
ON
Accumulated data
(OUT for which no hold is set)
RUN output OFF
ON
BUSY output OFF
ON
Accumulated data
(OUT for which hold is set)
Accumulate values according to the hold setting.
Output value according to the hold setting
Accumulate data once every three measurements
Measurement
time