SECTION 3
Setting Measurement Conditions (Expert Menu)
Compensating for Position Shift in the Height and Potion
Directions
Set the area for measuring the amount of position shift. The measurement value at this point is
registered as the reference position; place the workpiece at the correct position before starting
the settings.
This function can only be used when [Height] is selected as the detection method.
Height
direction
Position direction
Sensor
Sensor
Region used for measuring the amount of position shift
Set this level at a location where the target edge
can be detected even if the workpiece moves horizontally.
Position registered as the reference
Height registered as
the reference
Set this region at a location where the height always
remains the same, or where the shape of the workpiece can
be measured using the region as the reference.
Edge detection level for measuring the amount of position shift