Dimensions
PRECAUTIONS FOR CORRECT USE
INSTRUCTION SHEET
©
OMRON Corporation
2005-2015
All Rights Reserved.
Model
ZFV-XC
□
B(R)V2
Extension Cable
1. Be sure to observe the specifications and ratings when
using the Extension Cable.
2. Before connecting/disconnecting the connectors,
make sure that the Amplifier Unit is turned OFF. The
Extension Cable may break down if it is connected or
disconnected while the power is ON.
3. This Extension Cable can be daisy-chained to only
more cable. Note, however, that this Extension Cable
cannot be daisy-chained to the ZFV-XC
□
A and the
ZFV-XC
□
B(R).
4. Fasten the connector connections of this product
before use to prevent this product from moving.
5. The circuit is embedded in the ZFV-XC
□
B(R)V2
extension cable. Do not expose it to a strong vibration
and shock. An excessive vibration and shock may
cause the failure.
6. Avoid wiring the cable between the Sensor Head and
Amplifier Unit including this product near high
voltage lines and power lines.
Wiring them together or placing them in the same duct
may cause induction, resulting in malfunction or
damage.
■
Cleaning
Do not use paint thinner, benzene, acetone, or kerosene
for cleaning.
Thank you for selecting OMRON product. This sheet
primarily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your
convenience, keep the sheet at your disposal.
Note 1. Available cable lengths are 3 m and 8 m.
Mounting
holes
Mounting hole dimensions
2-M3
PVC insulated round cable 6.2 mm dia.
33
75
13
8.5
45.9
L (Note 1)
28
±
0.1
28
36
30
2-
φ
3.5
20 pins
20 pins
(Unit: mm)
* crooked-proof specification.
■
Specifications
ZFV-XC3BV2
Item
Model
Amplifier Unit
Applicable Sensor Head
Ambient temperature
Ambient humidity
Connection method
Approx. 220g
Materials
Cable length
Accessories
3m
ZFV-XC8BV2
ZFV-A Series / ZFV-CA Series
ZFV-S Series
Operating: 0 to 40
℃
, Storage -25 to +65
℃
(with no icing or condensation)
Operating and storage: 35 to 85% RH
(with no icing or condensation)
Double-end connector
Approx. 500g
Case: Polycarbonate (PC)
8m
Ferrite core(2 pieces), Instruction Sheet(this paper)
ZFV-XC3BRV2*
Approx. 220g
3m
Weight
Please observe the following precautions for safe use of the
product:
1. Do not use the product in environments where it can be
exposed to inflammable/explosive gas.
2. Do not disassemble, repair or modify this product.
3. Be sure to make sure that locking mechanisms are locked
before use.
4. Dispose of this product as industrial waste.
PRECAUTIONS FOR SAFE USE
Ambient environment
Degree of protection
No corrosive gases
IEC60529 IP20
Vibration resistance
10 to 150 Hz ; half-amplitude: 0.35mm,
maximum acceleration: 50 m/s
2
,
10 times for 8 minutes each in 3 directions
Shock resistance
150 m/s
2
, 3 times each in 6 directions
Indicates a potentially hazardous situation which, if not avoided, will
result in minor or moderate injury, or may result in serious injury or
death. Additionally there may be significant property damage.
This product is not designed or rated for ensuring safety
of persons. Do not use it for such purpose.
Do not disassemble or touch the interior while the
power is ON. This may cause an electric shock.
Do not touch the terminals while the power is ON.
This may cause an electric shock.
Meaning of Alert Symbols
Alert statements
WARNING
WARNING
PRECAUTIONS ON SAFETY
NOTICE:
This product meets CISPR11 class A. The intended use of this product
is in an industrial environment only.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
TRACEABILITY INFORMATION:
Importer in EU :
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters