Mounting and Connecting Devices
28
ZG User’s Manual
Mounting the ZG-WDS3T
Fix by mounting screws making sure that the distance between the Sensor and
measurement target is matched.
Mounting method
Fasten the Sensor onto the mounting base
with M4 screws.
Tightening torque: 1.2 N•m
For details on the positions of screw holes,
check the external dimensions in “Chapter 5
APPENDICES.”
External dimensions p.166
Mounting position
Mount the Sensor according to the following distances and angle.
The default mounting state of the Sensor is for diffuse reflection measurement. To set the
Sensor for diffuse reflection measurement, change the Sensor mounting setting.
Setting the Sensor Installation Status p.100
Important
Mounting for regular reflection
measurement
Emission axis
Reception axis
20 mm
25°
Measurement target
Mounting for diffuse reflection
measurement
Emission axis
Reception axis
5.2 mm
Measurement target
50°
N
ot
e
Summary of Contents for ZG -
Page 12: ...10 ZG User s Manual MEMO ...
Page 44: ...Overview of Settings and Measurement 42 ZG User s Manual MEMO ...
Page 60: ...Functions Operations Used during Operation RUN Mode 58 ZG User s Manual MEMO ...
Page 110: ...System Settings 108 ZG User s Manual MEMO ...
Page 156: ...Serial Communication 154 ZG User s Manual MEMO ...
Page 206: ...204 ZG User s Manual MEMO ...
Page 207: ...205 ZG User s Manual 5 APPENDICES MEMO ...
Page 208: ...206 ZG User s Manual MEMO ...