118
S
ect
io
n
7
AP
P
E
N
D
IC
E
S
ZJ-SD
User’s Manual
Section 7
Specifications and Dimensions
(*1)
The measured value is sometimes saturated and correct values are not displayed when the distance to the
sensing object is short even if it is inside the measurement voltage range.
(*2)
The minimum value that can be read when an Amplifier Unit (ZJ-SDA11) is connected
(*3)
When the ambient temperature is fixed at 25°C
(*4)
When the measuring distance is 10 mm and measurement voltage is -5 KV to +5 KV
(*5)
In the case of a preamplifier (excluding Sensor Head)
Item
ZJ-SD100
Applicable Amplifier Unit
ZJ-SDA11
Measurement distance
5 to 100 mm
Max. measurement voltage (*1) Standard mode: ±50 KV, high-precision mode: ±5 KV
Resolution (*2)
Standard mode: 10 KV, high-precision mode: 1 KV
Linearity (*3)
±5%FS (*4)
Ambient temperature
Operating/storage: 0 to +50°C
Ambient humidity
Operating/storage: 35 to 85%
Response time
20 ms
Dialectic strength
1,000 VAC, 50/60 Hz for 1 min (*5)
Vibration resistance
Sensor Head: 10 to 55 Hz, 3-mm double amplitude, 45 min each in X, Y and Z directions
Preamplifier: 10 to 55 Hz, 1.5-mm double amplitude, 2 H each in X, Y and Z directions
Degree of protection
IP20
Materials
Sensor Head: SUS
Preamplifier: PC
Weight (packed state)
Approx. 150 g
Accessories
Instruction sheet, ferrite core, mounting bracket
operation2.book Page 118 Wednesday, November 29, 2006 2:56 PM