32
Se
c
tion 3
BASI
C
OPE
RATION
ZJ-SD
User’s Manual
Section 3
Basic Knowledge for Operation
Inputting Numeric Values
This section describes how to input numeric values for threshold and output settings. This
section describes how to input directly, using an example of inputting the low threshold.
Changing the low threshold from "40.000" to "39.000"
Moving to the T mode
1.
Set the mode switch to T.
Setting threshold values
2.
Set the switch to L.
The measured value is displayed on the main display.
The current setting value is displayed on the sub-display.
3.
Press any cursor key.
The first digit on the sub-display flashes to indicate that
direct input is enabled.
4.
Use the UP and DOWN keys to display "3".
5.
Use the LEFT or RIGHT key to move the
cursor to the one's digit.
6.
Use the UP and DOWN keys to display "9".
To cancel the selected setting, use the LEFT key to move
the cursor to the leftmost digit and press the LEFT key
again. Alternatively, use the RIGHT key to move to the
rightmost digit and press the RIGHT key again. The display
will return to the current setting ("40.000" in this example).
7.
Press the ENT key to confirm the settings.
The display stops flashing and stays lit, and the setting is
registered.
operation2.book Page 32 Wednesday, November 29, 2006 2:56 PM