Section 5
Linear Output
Output Settings for Non-measurement
The linear output method for when a reset is input can be set.
• In the case of hold measurement
Even if [KEEP] is set, the output before the first hold value is obtained is the same as [CLAMP].
• Even in FUN mode, the outputs are made according to the non-measurement settings.
Moving to the FUN mode and SPCL
1.
Set the mode switch to FUN.
2.
Use the LEFT and RIGHT keys to display
[SPCL] on the main display.
Moving to RESET
3.
Press the UP or DOWN key.
The sub-display flashes.
4.
Use the UP and DOWN keys to display [ETC]
or [ALL].
5.
Press the ENT key.
Selection
Outputs
Judgment outputs
Linear output
KEEP
(default)
The measured value immediately before measurement is stopped is held and output.
CLAMP
All outputs turn OFF.
The set CLAMP value is output.
The following options are available:
• At current output: 3 to 21 mA or maximum
(approx. 23 mA)
• At voltage output: -5 to 5 V or maximum (approx.
5.5 V)