82
S
e
ct
ion 5
DETAILE
D
S
E
TTINGS
ZJ-SD
User’s Manual
Section 5
Setting the Warning Level (Output type)
Setting the Warning Level (Output type)
Threshold values (warning level) other than HIGH, PASS or LOW can be set and displayed.
■
Judgment output (judgment indicator)
OK: Judged as PASS
NG: Other than PASS (HIGH or LOW)
WARN: ON in warning state
Peak-OK: ON when the peak hold result is OK (PASS)
Bottom-OK: ON when the bottom hold result is OK (PASS)
Selection
Details
STAND
(standard)
(default)
The warning level is not set.
Only the HIGH, PASS or LOW
judgments are output.
When timer = OFF
WARN
(warning)
The warning level is set.
Next, specify the warning level value.
• The warning status
continues to be output until
one of "reset input ON",
"switching to FUN mode" or
"power OFF".
• The warning level value is
set to the plus and minus
directions.
(Example: When "15" is
specified, the +15 and -15
become the warning level
values.)
When timer = OFF
Hold
Output type
OPE1
OPE2
OPE3
Other than peak and bottom
hold
Standard
HIGH
PASS
LOW
Warning
WARN
OK
NG
Peak and bottom hold
Not related
WARN
Peak-OK
Bottom-OK
ON
OFF
ON
OFF
ON
OFF
Measured value
HIGH output
PASS output
LOW output
HIGH threshold
LOW threshold
ON
OFF
Reset input ON
ON
OFF
ON
OFF
Measured value
HIGH threshold
LOW threshold
Warn output
OK output
NG output
Warning level
(- side)
Warning level
(+ side)
operation2.book Page 82 Wednesday, November 29, 2006 2:56 PM