PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Observe the following precautions to ensure safe operation.
· Places subject to exposure to water, oil, or chemicals
· Dispose of the Fine Differential Pressure Sensor as industrial waste.
· Do not subject the product to a shock by an accident such as dropping the
product. Doing so may cause damage to or malfunction of the product. To
prevent damage from dropping the product, secure screws to the wall
surface. If strong impact is applied to the product, stop use of the product.
■
Applicable standards
・
EN61326-1
・
Electromagnetic environment : Industrial electromagnetic environment
(EN/IEC
61326-1
Table 2)
1. Avoid installing the product in the following places:
· Places exceeded the rated ambient temperature
· Places exposed to extreme temperature changes (prevent condensation.)
· Places exceeded the rated RH level
· Places subject to corrosive or flammable gases
· Places subject to mist, droplets, coarse particles, fiber, salt, metal dust, or
large amount of particles
· Places subject to direct shock or vibration
· Places subject to direct sunlight
· Places subject to exposure to water, oil, or chemicals
· Places subject to strong magnetic field or electric field
2. Wiring
· Lay the product cable away from any high-voltage cable or power line. If
laid in the same conduit or duct, induction noise from them may cause
malfunction or breakdown of the product.
· Do not connect the product to a controller other than ZN-DPX
□□
-S. Do
not hold this sensor alone with the controller mounted (where the controller
mounted).
3. Fine differential pressure measurement
· To conduct measurement, fine air flow will be required. To conduct
accurate measurement, shorten the air tube length to be connected as much
as possible and do not bend or fold the air tube. Connecting a bent air tube
or air tube with a length of more than 1 m may cause failure of proper
measurement.
· When installing the air tube on the wall, be careful for vibrations not to
be transmitted to the air tube. Failure to do so may cause failure of
proper measurement.
4. Others
· Do not apply pressure that exceeds the rated pressure. Doing so may
cause malfunction or damage of the product.
* For the precision under a rated environment, an offset less than 0.1 Pa/year may
occur.
Secure the product on the wall, etc. using screw holes.
M3x8 screws are provided.
Insert the air tube into the pressure inlet. There are inscriptions at the high pressure
side (
▼
Hi) and low pressure side (
▼
Lo) at the top of the pressure inlet. Properly
connect air tubes according to a subject to be measured. When pressure at the high
pressure side is high, the measured value is positive, and when pressure at the low
pressure side is high, the measured value is negative.
Item
Differential
pressure
Temperature
effect
Operating temperature range
Storage temperature range
Operating humidity range
Storage humidity range
Applicable gas type
Vibration resistance
Shock resistance
Degree of protection
Material
Mounting method
Applicable air tube diameter
Weight (packaged)
Accessories
Measurement range
Resolution
Zero point
Span
Measurement precision
Model
–500 to +500 Pa
0.1 Pa
3%±0.2 Pa of the measured value (at 23
℃
, 966 mbar)*
No effects (lower than measurement resolution)
Less than 0.5% of the specified value/10
℃
0 to 50
℃
–15 to +50
℃
(no condensation or icing)
35 to 85%RH (no condensation)
IP30
ABS
Screw mounting
Outside diameter 6 mm, inside diameter 4 mm
Approx. 500 g
Instruction Sheet, air tube 1 m x 2,
mounting screw (M3x6) x2
35 to 85%RH (no condensation or icing)
Air, nitrogen
150 m/s
2
in 6 directions (+/-X, +/-Y,
and +/-Z directions), 3 times each
10 to 150 Hz, 0.7 mm double amplitude
acceleration : 50 m/s
2
for each in X, Y and
Z directions for 80 min
■
Ratings/Characteristics
■
Model Number Legend
■
Calibration
ZN-DPS1
□
-S
■
Dimensions
■
Mounting
Insert the connector (male) of the product into the sensor head connector (female) of
the controller.
Install the product according to the mounting method described in the Instruction
Sheet of the controller.
Be sure to contact OMRON for the calibration of the differential pressure sensor head.
When sending the sensor head to OMRON, take care to prevent foreign substances
from entering into the sensor head.
Z N - D P S 1
□ □
- S
With or without a calibration certificate
(No symbol: Without certificate,
C: With certificate)
Product series name
Differential pressure sensor head and
measurement method
Connection type distinction
(1: Cable length at 1.5 m,
5: Cable length at 10 m)
(Unit: mm)
44.4
32±0.2
Mounting hole process
dimensions
Low pressure
side inlet
High pressure
side inlet
2-M3
26±0.2
2 - 3.5 Dia.
mounting hole
21
32
10.5
3.5 Dia.
3.5 Dia.
10.5
22.5
15.8
12.6
2.7
13.9
26
16.7
8.7
59.6
Vinyl-insulated round cable: 3.4 Dia., 3-wire
(Cross section of conductor: 0.08 mm
2
/Insulator diameter: Dia. 0.95 mm)
Standard length: 1.5 m
High pressure side
Low pressure
side
Air tubes
Mounting screws (M3)
Insert air tubes up to
this position.
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
TRACEABILITY INFORMATION:
Importer in EU :
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
ZN-DPS1
□□
-S
Fine Differential Pressure Sensor Head
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet primarily
describes precautions required in installing and operating the product.
Before operating the product, read the sheet thoroughly to acquire
sufficient knowledge of the product. For your convenience, keep the
sheet at your disposal.
©
OMRON Corporation
2011-2018
All Rights Reserved.
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters
Dispose of in accordance with WEEE Directive