background image

Please observe the following precautions for safe use of the product.

1. Do not use this product in environments where it can be exposed to 

inflammable/explosive gas. 

2. In order to secure the safety of operation and maintenance, do not install 

this product close to high-voltage devices and power devices. 

3. Use the power supply within the specified voltage range. 

4. Do not disassemble, repair, or modify this product.

5. Dispose of this product as industrial waste.

 Applicable standards

EN61326-1

Electromagnetic environment : Industrial electromagnetic environment 

 

              

(EN/IEC

61326-1

Table 2) 

(1) Power switch

  Turns the power supply ON/OFF. 

(2) Error output indicator

  This indicator lights red during an error output. 

(3) Cleaning notice/warning indicator

  This indicator flashes orange to notify you that the discharge needles are dirty and 

the product's neutralizing capabilities are about to drop. This indicator will stop 

flashing and stay lit when the discharge needles become even dirtier and the 

product's neutralizing capabilities can no longer be sustained. 

(4) Power indicator

  This indicator lights green when the power is ON. 

(5) Ion balance adjustment button

  Pressing this button adjusts the ion balance. 

(6) Power input/signal output connector

  Power can be supplied and output managed via this connector when the Air Clean 

Unit is connected. 

  When the Air Clean Unit is not connected, 24 VDC power can be input. The 

cleaning notice, cleaning warning operation (Unit turned OFF when a warning is 

output) and error output (Unit turned OFF when an error is output) can be output. 

(7) GND terminal

  Terminal for connecting the ground 

(8) AC adapter terminal

 nonuse

The following summarizes the colors and wiring of the I/O cable provided with the 

ZN-J25, and output specifications. 

*1  Measurement conditions: 

  Distance: 300 mm, Air Clean Unit: ZN-A2502 with air level 5, At center of air 

outlet, Neutralization: From 

±

1000 V down to 

±

100 V with Charge Plate 

monitor (150 x 150 mm, 20 pF)

  Temperature: 18

 to 28

  Humidity: 35% to 55%

  The performance might not be able to be satisfied when there is gas such as 

solvent gas in the measurement area. 

*2  Measurement conditions:

  Distance: 300 mm, Air Clean Unit: ZN-A2502 with air level 5, At center of air 

outlet, Measurement time: 10 seconds

  Temperature: 18

 to 28

  Humidity: 35% to 55%

  The performance might not be able to be satisfied when there is gas such as 

solvent gas in the measurement area. 

(9) Discharge needles

  Ions are generated by applying a high voltage to these discharge needles and 

discharging corona. 

(10) Ion balance sensor

 

This sensor detects the balance of the ions emitted from the discharge needles, and 

this information is used as feedback to automatically control the ion balance. 

(11) Mount holes

 

Holes for mounting this product on an Air Clean Unit, clean booth panel or other 

equipment 

■ 

Part Names and Functions

■ 

Outline and Features

■ 

Label Replacement

■ 

Ratings/Performance

 I/O and Wiring

PRECAUTIONS FOR SAFE USE

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet primarily 

describes precautions required in installing and operating the 

product.

Before operating the product, read the sheet thoroughly to acquire 

sufficient knowledge of the product. For your convenience, keep 

the sheet at your disposal.

© OMRON Corporation  2006-2007  All Rights Reserved. 

Model 

ZN-J25A

Air Clean Ionizer

Please observe the following precautions to prevent failure to operate, malfunctions, 

or undesirable effects on product performance.

1. Installation Site

  Do not install this product in locations subjected to the following conditions:

• Ambient temperature outside the rating

• Ambient humidity outside the rating

• Presence of corrosive or flammable gases

• Presence of dust, salt, or iron particles

• Presence of particles and dust

• Direct vibration or shock

• Direct sunlight

• Water, oil, or chemical fumes or spray

• Devices (e.g. precision equipment) susceptible to the influence of peripheral 

noise

• Strong magnetic or electric field, and charged objects

* Precautions for Installation and Use

  The two metal bars on the enclosure opening are sensor electrodes. The ion 

balance can no longer be controlled if charged objects are located around this 

product. Do not bring charged objected within about 150 mm of this product. 

2.  Power Supply and Wiring

• When using a 24 VDC power supply:

  Connect the 24 VDC power supply to the rear connector using the I/O cable. 

When supplying power by the I/O cable, do not connect the AC adapter at the 

same time.

  Do not ground the 24 VDC terminal. 

• When supplying power from the Air Clean Unit:

  Connect the power supply to the ZN-J25A using the exclusive cable (provided). 

Do not connect the AC adapter at the same time. 

• If surge current is present in the power lines, connect surge absorbers that suit 

the operating environment.

• When connecting the power and output lines, pay attention to the polarity of the 

lines.

  The supply voltage must be within the rated range.

• When connecting the power line, do not short-circuit the power supply.

• When connecting the output line, the supply current must be within the rated 

range.

• Always ground the GND terminal. Using the product without the GND 

terminal grounded may cause the ion balance to deviate. 

• High-voltage lines and power lines must be wired separately from this product.

  Wiring them together or placing them in the same duct may cause induction, 

resulting in malfunction or damage.

3.  Maintenance and Inspection

• Periodically clean the discharge needles as dirt on these needles causes the 

amount of generated ions to fall or the ion balance to deviate.

• Always wait at least one minute after turning the power supply OFF before 

cleaning or connecting/disconnecting the discharge needles. 

• Do not touch the discharge needles directly with your hands.

• Use ethanol or isopropyl alcohol to clean the discharge needles. Do not use 

paint thinner, benzene, acetone or kerosene.

• This product neutralizes static electricity on charged objects by ionizing air by 

corona discharge and spraying ions at charged objects from an Air Clean Unit. 

• An Air Clean Unit (ZN-A2502, sold separately) can also be installed and connected 

to this product at the same time. This eliminates the need for individual installation 

and wiring of the Ionizer.

• Compared with bar-type ionizers, this product can be installed with minimal 

blocking of laminar airflow from an Air Clean Unit.

• The Auto Ion Control function keeps the ion balance in an optimum state.

The warning labels written in Japanese are affixed to the body. For countries 

other than Japan, warning labels must be replaced by English ones (supplied with 

the product).

PRECAUTIONS FOR CORRECT USE

PRECAUTIONS ON SAFETY

● 

Meanings of Signal Words

● 

Alert Statements in This Instruction Sheet

Indicates a potentially hazardous situation which, if not 

avoided, will result in minor or moderate injury, or may 

result in serious injury or death. Additionally, there may be 

significant property damage.

WARNING

When screw-fastening the body for use, vibration or the 

body’s own weight may cause it to fall, and cause an injury 

if the screws are not sufficiently tightened.

Mount the body using M4 screws tightened to a tightening 

torque of 1.2 to 1.6 N.m.
Water droplets entering the body and coming into contact 

with the electrical circuit may cause the circuit to ignite.

Do not use the product in locations subjected to 

condensation or in highly humid atmospheres.

WARNING

(4) (3) (2)

(1)

(8)

(7)

(6)

(5)

(11)

(9)

(10)

(11)

Specifications

Model

Power supply voltage

Current consumption

Output voltage

300 mA max.

±

7kV max.

Variable DC

5 sec max.

±

30 V max.

Power (Green)

Cleaning notice (Orange flashing)

Cleaning alarm (Orange)

Error (Red)

Error output, cleaning notice/alarm output: 

photo MOS relay (30 VDC 300 mA max.)

Manual Ion balance adjustment, 

cleaning alarm, error alarm

Operating and storage: 0 to 40

(with no icing or condensation)

Operating and storage: 35 to 65% 

(with no condensation)

Case: ABS, Discharge needles: Tungsten

248 (W) × 310 (D) × 45 (H) mm

Approx. 0.6 kg (approx. 1.4 kg)

Instruction sheet

Sealing parts

Mounting screws

Connector cable for 

Air Clean Unit

Ferrite core

English warning label

Discharge method

Neutralizing time 

(typical) *1
Ion balance

(typical) *2 

Indicators

Outputs

Functions

Ambient temperature

Ambient humidity

Dimensions

Materials

Weight (packed state)

Accessories

Item

Available air clean 

unit

24 VDC

±

10% ripple (p-p) 10% max.

ZN-J25A

ZN-A2502

(1) Wire Colors and Wiring

(2) Output specifications

Output

voltage

30 VDC

300 mA max.

Load

current

Internal

circuit

IC

Outputs

(blue, yellow, green)

CN No. (1, 2, 3)

Load

When this product is used in a closed space, ozone may 

accumulate, which is harmful to the body. 

Ventilate the installation site well during use.

CAUTION

Common (red)

CN No. (4)

Signal

Error output

Cleaning warning output

Cleaning notice output

Common output

0 V input

24 V input

Wire Color

Blue

Yellow

Green

Red

Black

White

CN No.

1
2
3
4
5
6

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

TRACEABILITY INFORMATION:

Importer

 in EU :

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

*

9

9

7

5

4

5

6

-

1

G

*

For wire used for a terminal block,consider the following.

Wire length

30m and less

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

Summary of Contents for ZN-J25A

Page 1: ...できな くなります 本製品の周囲約 150mm以内に帯電物を近づけないでください 2 電源および配線について DC24V 電源を使用する場合 入出力ケーブルを用いて背面コネクタに接続ください 入出力ケーブ ルより電源供給する場合 同時に AC アダプタは接続しないでくださ い DC24V 端子を接地しないでください エアクリーンユニットより電源を供給する場合 形 ZN J25A に付属の専用のケーブルで接続してください 同時に AC アダプタは接続しないでください 電源ラインにサージが確認された場合 環境に応じてサージアブソー バを接続ください 電源ライン 出力ライン接続時には 極性に注意して接続してください また 定格を超える電圧を印加しないでください 電源ライン接続時は 電源を短絡しないでください 出力ライン接続時は 定格を超える電流を流さないでください 接地端子は必ず接地してください...

Page 2: ...付け 放電針ホルダを取外すと き にはホルダを左に回して 引き抜き ます 放電針ホルダを取付ける と きはホルダを奥まで差込み 右に回し ます 放電針の清掃 綿棒などにエタ ノ ール ま たはイ ソ プロ ピルアルコールを含ませ 放電針 先端部の汚れをふき取って く だ さ い 放電針ホルダは無理に引き抜こ う と した り し ますと破損し ます かな らず左 に回し き ってか ら引き抜いて く だ さ い 放電針の先端は触ら ないよ う お願い し ます ま た傷つけた り 曲げた りす る と性能が低下し ます 除電性能を維持するために 放電針は当社指定の放電針を ご使用く だ さ い 清掃後も性能が復帰しない場合は 放電針の交換を行って く だ さ い 必 ず下記の当社指定のものを ご使用く だ さ い 別売品 放電針 針ホルダ付 形 ZN9 JH04 4 セ ッ ト 入り パー...

Page 3: ...he exclusive cable provided Do not connect the AC adapter at the same time If surge current is present in the power lines connect surge absorbers that suit the operating environment When connecting the power and output lines pay attention to the polarity of the lines The supply voltage must be within the rated range When connecting the power line do not short circuit the power supply When connecti...

Page 4: ...ohol and wipe off dirt from the tip of the discharge needle Using unnecessary force to pull out the discharge needle holder will damage it Always turn the discharge needle holder anticlockwise as far as possible before pulling it out Take care not to touch the tips of the discharge needles Also scratching or bending the tip will cause neutralizing performance to drop To sustain the Unit s neutrali...

Reviews: