Section6
I/
O
Section6
Settings for Terminal Block Output
6-11
ZS-HL
User’s Manual
Output Format
■
When the measured value is output
The measured value is converted to 16-bit binary data in the maximum steps of 65536,
and is output. The following table lists the correspondence between the measured
value and 16-bit binary data.
• When Only a Task is Output
Data output value of parallel data
16-bit binary data (in binary)
In decimal
CLAMP-LV
NEAR side
CENTER
D15-D12 D11-D8
Data that is output from a 16-bit terminal block
In the above table,
• 1 indicates that the open-collector output is ON (For NPN type, L level, and for PNP type, H level).
• 0 indicates that the open-collector output is OFF (For NPN type, H level, and for PNP type, L level).
Becomes CLAMP-LV when a
measurement error occurs.
D7-D4
D3-D0
65535
52768
48768
44768
40768
36768
32769
32768
32767
28768
24768
20768
16768
12768
1111
1100
1011
1010
1001
1000
1000
1000
0111
0111
0110
0101
0100
0011
1111
1110
1110
1110
1111
1111
0000
0000
1111
0000
0000
0001
0001
0001
1111
0000
0000
0000
0000
0000
0001
0000
1111
0000
0000
0000
0000
0000
1111
0010
1000
1110
0100
1010
0000
0000
1111
0110
1100
0010
1000
1110
FAR side
Measuring range
At default,
data is output
in 40,000
steps from
12,768 to
52,768.
1111
0000
0000
0000
0000
0000
0000
1111
0101
0100
0011
0010
0001
0000
1111
0011
1100
0101
1110
0111
0000
1111
1100
1001
0111
0100
0010
0000
Output value after FOCUS is performed (in decimal) 16-bit binary data (in binary)
Data output value of parallel data
65535
50000
40000
30000
20000
10000
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
b15 b14 b13 b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
=10000
D15-D12 D11-D8
Level that is output from the 16-bit terminal block
D7-D4
D3-D0
When FOCUS is set for the first point (measured value 0.000
→
output value 00000)
and second value (measured value 10.000
→
output value 20000).
When the measurement result is 5000, 10000 is output in binary.
Example:
b15 b14 b13 b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Binary data of the measured value
When FOCUS is set, only the measurement that reflects the FOCUS setting is output.
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...