Section6
I/
O
Section6
Settings for Terminal Block Output
6-13
ZS-HL
User’s Manual
Setting Focus
Enter the measured values for any two binary output values to set the output range.
(default value: OFF)
Example: Set 0 mm to 0 and 5 mm to 50000. (when ZS-HLDS5 is connected)
Separate the two specified points by at least 1 % of the rated measurement range for the connected
Sensor Head.
Example: For the ZS-HLDS5T
The two measured points must be separated by at least “10 mm × 0.01 = 0.1 mm” as the measuring
range is “±5 mm (10 mm)”.
X
FUN mode-[I/O SET]-[TERMINAL]-[FOCUS]-[ON]
1.
Set the binary output value of point 1.
The output value is displayed on the main
display.
2.
Press the SET Key to apply the setting.
3.
Set the measured value for point 1.
The measured value is displayed on the sub-
display.
4.
Press the SET Key to apply the setting.
5
32767
0
65535
-5
0
5
32767
0
65535
-5
0
52768
12768
50000
Output value
Measured value
(mm)
Output value
Measured value
(mm)
INPUT POINT 1
DIG
VAL SET:OK
INPUT POINT 1
DIG
VAL SET:OK
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...