6-20
Section6
I/
O
ZS-HL
User’s Manual
Section6
Timing Charts
■
Sample Hold
This is the timing charts when the trigger mode is external trigger.
When you fetch the output result of the terminal block, fetch it on the falling edge of the GATE signal.
The terminal block is set when the judgment value output and judgment TASK1/2/3/4 output are set.
When the measured value is output continuously, it is output continuously according to the sampling
cycle, but not according to the trigger input.
The result to be output is the one that is processed at the timing drawn in diagonal line.
Item
Minimum
Aver-
age
Maximum
Remarks
T2
Minimum time of trigger
input
Sampling cycle × 4 –
–
T12 Timing of starting and end-
ing the measurement after
trigger input
Sampling cycle × 3 –
Sampling cycle × 4
T13 Response time of judgment
output, BUSY output, and
terminal block output
Sampling cycle × 4 –
Sampling cycle × 5 When the terminal
block output is in
the update cycle 1
T10 OFF time of GATE signal
68 µs
T21 Response time of GATE
signal
320 µs
T11 Response time of linear
output
–
–
500 µs
It changes depend-
ing on the way the
measured value
fluctuates.
OFF
ON
OFF
ON
Trigger input
Trigger rest input
Internal processing
Judgment output
BUSY output
Terminal block output
Linear output
T10
T21
T2
T12
T12
T13
T13
T13
T10
T21
T11
T11
OFF
ON
OFF
ON
T2
GATE signal
Summary of Contents for ZS--LD10GT
Page 1: ...Smart Sensor 2D CMOS Laser Type Cat No Z236 E1 02A ZS HL Series USER S MANUAL ...
Page 32: ...1 10 Section 1 FEATURES ZS HL User s Manual Section 1 Setting Flow MEMO ...
Page 52: ...2 20 Section2 INSTALLATION CONNECTION ZS HL User s Manual Section2 SmartMonitor ZS MEMO ...
Page 104: ...5 30 Section5 SETTINGS FOR FUNCTIONS ZS HL User s Manual Section5 Clearing the Settings MEMO ...
Page 206: ...9 20 Section9 APPENDIX ZS HL User s Manual Section9 Updating Firmware MEMO ...
Page 210: ...9 24 ZS L User s Manual Section9 Index Section9 APPENDIX MEMO ...