6-26
Section6
I/
O
ZS-HL
User’s Manual
Section6
Timing Charts
■
Operations in FUN Mode and When the Mode is Switched from
FUN to One Other Than FUN
In FUN mode, the value is not output to the terminal block (ZS-RPD). Immediately after the mode is
switched to one other than FUN mode, a clamp value is output until the measured value is deter-
mined.
Item
Minimum
Average
Maximum
Remarks
T11 Response time of linear
output
–
–
500 µs
It changes depend-
ing on the way the
measured value
fluctuates.
T19 Response time of mode
switching
–
–
Sampling cycle
T20 Determination time of valid
data after mode switching
–
–
Sampling cycle
× (15 + average
number)
Mode
Laser beam emission
Internal processing
Linear output
T19
T20
T11
T19
Except for FUN mode
FUN mode
ON
OFF
Summary of Contents for ZS--LD10GT