EtherCAT Connection
168
ZW User's Manual
Sensor Head1
Status Flag
Sensor head 1 status
signal
HOLDSTAT1
HOLDSTAT1
Hold execution status
Turns ON when the displacement sensor is in the hold
sampling period.
Turns OFF when the displacement sensor is outside the
hold sampling period.
RESETSTAT1
RESETSTAT1
Reset execution state
Turns ON when the displacement sensor is in the reset
execution state.
Turns OFF when the displacement sensor is in the reset
non-execution state.
LIGHT1
LIGHT1
Logical beam lighting
state
Turns ON when the logical beam is lit.
Turns OFF when the logical beam is out.
STABILITY1
STABILITY1
Measurement position
Turns ON when the measured value is in the measuring
range.
Turns OFF when the measured value is outside the
measuring range.
ENABLE1
ENABLE1
Measurement state
Turns ON when the displacement sensor is ready for
measurement.
Turns OFF when the displacement sensor cannot measure
(excessive or insufficient received light, outside measuring
range, Calibration ROM not mounted, during FUN mode
non-measurement).
GATE1
GATE1
Data output completed
Turns ON when the displacement sensor completes
control data output when hold is set.
The displacement sensor automatically turns OFF one
Gate period after turning ON.
OR1
OR1
Overall judgment result
Turns ON when even one of the judgment result of the
displacement sensor TASK1 to 4 is other than PASS.
Turns OFF when all of the judgment result of the
displacement sensor TASK1 to 4 is PASS.
HIGH1_T1 to 4
HIGH1_T1-4
HIGH output
Turns ON when the judgment result of the displacement
sensor TASK1 to 4 is HIGH (HIGH threshold < measured
value).
Turns OFF when the judgment result of the displacement
sensor TASK1 to 4 is other than HIGH.
PASS1_T1 to 4
PASS1_T1-4
PASS Output
Turns ON when the judgment result of the displacement
sensor TASK1 to 4 is PASS (LOW threshold
measured
value
HIGH threshold).
Turns OFF when the judgment result of the displacement
sensor TASK1 to 4 is other than PASS.
LOW1_T1 to 4
LOW1_T1-4
LOW output
Turns ON when the judgment result of the displacement
sensor TASK1 to 4 is LOW (LOW threshold > measured
value).
Turns OFF when the judgment result of the displacement
sensor TASK1 to 4 is other than LOW.
ZEROSTAT1_T1 to
4
ZEROSTAT1_T1-4
Zero reset state
Turns ON when the displacement sensor TASK1 to 4 is in
the zero reset execution state.
Turns OFF when the displacement sensor TASK1 to 4 is in
the zero reset non-execution state.
Response
Command code
Command code
The executed command code is returned.
Response Code
Response code
Response code
The response code of the executed command is stored.
Response Data
Response data
Response data
The response data of the executed command is stored.
I/O port name
Signal
Signal name
Function
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......