EtherNet/IP Connection
220
ZW User's Manual
Timing Chart (EtherNet/IP)
●
Control command execution
(1) The command code and command parameter are set from the Controller.
(2) The EXE input signal state is changed from OFF to ON. Execution is instructed to the displacement sensor.
(3) When the displacement sensor receives the execution instruction, the READY output signal turns OFF and
the command is executed.
(4) When the displacement sensor completes execution, the command code, response code and response
data are set.
(5) The FLG output signal turns ON.
(6) The Controller makes sure that the FLG output signal has turned ON, and then returns the EXE input signal
to OFF.
(7) The displacement sensor makes sure that the EXE input signal has turned OFF, and the FLG and READY
output signals automatically turn OFF and ON, respectively.
Command Code
Command
Parameter
EXE inp
u
t
Command Code
Response Code
Response Data
FLG o
u
tp
u
t
O
N
OFF
O
N
OFF
O
N
OFF
O
N
OFF
READY o
u
tp
u
t
O
N
OFF
O
N
OFF
O
N
OFF
O
N
OFF
(1)
(2)
(4)
(5) (6)
(3)
(7)
Command
Area
Response
Area
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......