Error Messages
ZW User's Manual
275
8
Tro
uble
s
hootin
g
Event name
Linearity correction data read error
Event code
14B1 0000 Hex
Meaning
Reading of the displacement sensor linearity correction data was not executed correctly.
Source
EtherCAT master function module
Source details
Slave
Detection
timing
At displacement
sensor startup
Error attributes
Level
Minor fault
Recovery
Error reset
(after
cancellation of
slave error)
Log category
System
Effects
User program
Continues
Operation
An error message is displayed on the displacement
sensor's digital display, and the ALARM output of
parallel I/O turns ON. The displacement sensor is in a
stopped state until it is restarted.
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
System-defined
variables
Variable
Data type
Name
None
Cause and
correction
Assumed cause
Correction
Prevention
Calibration ROM not inserted
Turn the displacement sensor OFF,
insert the Calibration ROM and turn
the sensor ON again.
Calibration ROM damage
Calibration ROM may be broken.
Please contact an OMRON branch
or sales office.
Attached
information
None
Precautions/
Remarks
As a provisional measure, the measurement can be resumed using the data of the previously read Calibration
ROM.
<Operation method>
With error code 3 displayed on the sub-display, hold down the Mode switching key, then when [OK/CAN] is
displayed, press the ZERO/SET key.
<Cautions>
• When using this method, always check the serial number of the previously read Calibration ROM in "controller
information," then check that it matches the Sensor Head side serial number. Measurement will not be correct
unless they match.
• When restarting the main unit, perform the same operations again.
• This operation is disabled for a displacement sensor into which no Calibration ROM has ever been inserted
and started up.
Event name
System setting error
Event code
14B2 0000 Hex
Meaning
The system settings saved to the displacement sensor are corrupt.
Source
EtherCAT master function module
Source details
Slave
Detection
timing
At displacement
sensor startup
Error attributes
Level
Minor fault
Recovery
Error reset
(after
cancellation of
slave error)
Log category
System
Effects
User program
Continues
Operation
An error message is displayed on the displacement
sensor's digital display, and the ALARM output of
parallel I/O turns ON. The displacement sensor is in a
stopped state until it is restarted.
Indicators
EtherCAT NET RUN
EtherCAT NET ERR
EtherCAT LINK/ACT
System-defined
variables
Variable
Data type
Name
None
Cause and
correction
Assumed cause
Correction
Prevention
The displacement sensor power
was turned OFF during saving/
loading of system settings.
After holding down the Mode
switching key, press the ZERO/SET
key to clear the system settings and
the bank data, then resume the
starting process.
Do not turn the displacement
sensor OFF during saving/loading
of system settings.
Attached
information
None
Precautions/
Remarks
None
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......