Wiring
46
ZW User's Manual
Analog output terminal block
Used for analog output.
Compatible cable specifications: AWG 18 to 28, pin processed length: 7 mm
Cut the unnecessary signal lines so that they do not touch other signal lines. The length of Cables should be less than
30 m.
Class
Name
Description
Analog
output
OUT1 (V)
This outputs the measured value, from -10 V to +10 V as the voltage value.
When measurement not possible: Approx. +10.8 V (default value; can be selected by user)
Alarm: Approx. 10.8 V
OUT1 (A)
This outputs the measured value, from 4 mA to 20 mA as the current value.
When measurement not possible: Approx. +21mA (default value; can be selected by user)
Alarm: Approx. +21 mA
OUT1 0V
0 V for analog voltage output.
1
Loosen the two fixing screws using a screwdriver to
remove Analog output terminal block from the
Sensor Controller.
Signal name
No.
Signal name
OUT1(V)
1
4
NC
OUT1(A)
2
5
NC
OUT1 0V
3
6
NC
Important
Fixing Screws
(both end)
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......