Functions and Operations during Measurement
298
ZW User's Manual
9-5 Functions and Operations during Measurement
Switching the RUN (Run) Mode Display
In the RUN mode, you can switch the measured value display by pressing the
/
keys during the operation.
You can check the threshold value and analog output value while displaying the measured value on the main display.
The above display screenshots are only samples and may different from actual displays.
(Note 1) An output item not selected on the analog output (Voltage output/Current output) is displayed as "------
" on the sub-display. For example, if "Voltage output" is selected on the analog output, the analog
current output value is displayed as "------" on the sub-display.
(Note 2) "Displayed task" can be selected from TASK1 to TASK4. "Task for displayed target" is displayed as "dTASK
@
."
@
indicates the task number. (Refer to p.300 for the task for displayed target.) ) If the task for displayed
target is TASK2, for example, "TASK1, "dTASK2," "TASK3" and "TASK4" will be displayed.
Details Displayed on the Main Display
The measured values always appear on the main display.
The measured values are initialized as follows:
• Reference value "0": Measurement center distance
• + display: NEAR (close range) side
• - display: FAR (far range) side
However, in the following cases, the measurement values are not displayed.
• When the amount of light received is inadequate, "DARK" is displayed; when the sensor is saturated,
"BRIGHT" is displayed.
• When there is no surface present to measure, "NO.SRFC" is displayed.
• When the measurement LED is OFF, "LEDOFF" is displayed.
• When the measurement surface is far outside the measurement range or if no hold value is finalized when
hold is set, then "------" is displayed.
H lit
L
u
nlit
H
u
nlit
L lit
HIGH threshold
v
al
u
e
Analog
v
oltage
o
u
tp
u
t
v
al
u
e
J
u
dgement res
u
lt
LO
W
threshold
v
al
u
e
Analog c
u
rrent
o
u
tp
u
t
v
al
u
e
H
u
nlit
L
u
nlit
H
u
nlit
L
u
nlit
H
u
nlit
L
u
nlit
Resol
u
tion
H
u
nlit
L
u
nlit
(
N
ote 1)
(
N
ote 2)
Distance
Distance
Online stat
u
s
H
u
nlit
L
u
nlit
H
u
nlit
L
u
nlit
Link stat
u
s
H
u
nlit
L
u
nlit
H
u
nlit
L
u
nlit
H
u
nlit
L
u
nlit
Expos
u
re time
H
u
nlit
L
u
nlit
H
u
nlit
L
u
nlit
Tag link stat
u
s
H
u
nlit
L
u
nlit
Displayed Task for
displayed target
Task for
displayed target
H
u
nlit
L
u
nlit
Internal logging stat
u
s
Summary of Contents for ZW-C1*AT
Page 17: ...ZW User s Manual 1 15 ...
Page 54: ...Installing the Sysmac Studio 52 ZW User s Manual MEMO ...
Page 74: ...Operating with Sensor Controller 72 ZW User s Manual MEMO ...
Page 120: ...Setting the System 118 ZW User s Manual MEMO ...
Page 138: ...Controll input signal with PC tool 136 ZW User s Manual MEMO ...
Page 262: ...No protocol Connection 260 ZW User s Manual MEMO ...
Page 271: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 270 8 2 Troubleshooting 284 ...
Page 358: ...Connecting by No protocol Communications 356 ZW User s Manual MEMO ...
Page 449: ......