Controll input signal with PC tool
ZW User's Manual
131
5
Conve
n
ien
t Fu
nctions
5-8 Controll input signal with PC tool
Following input signal can be controlled with PC tool.
• LED-OFF
• TIMING
• RESET
• ZERO
Explorer pane
: [Bank] | [(Bank data Name)] (double click)
Edit pane
: [I/O input]
1
Select ON from [I/O input].
2
If the button is clicked, the Sensor Controller
is controlled as corresponding input signal
is turned ON.
While the button is clicked, corresponding input
signal is status ON.
If the button is clicked again, the input signal is
turned OFF.
Button
Effect
LED-OFF
The measurement LED is turned OFF.
TIMING
The TIMING input is turned ON.
RESET
The RESET input is turned ON.
ZERO
The ZERO input is turned ON.