Parallel I/O connection
136
ZW User's Manual
Bank number output
Binary output task number output
Binary output object task selection input
Name
Description
BANK_OUT output
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
Bank Number
BANK_OUT1
BANK_OUT2
BANK_OUT3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON
Name
Description
BINARY_OUT output
This outputs the task number currently output as binary.
It expresses the task number in combinations of BINARY_OUT1 and 2.
Task Number
BINARY_OUT1
BINARY_OUT2
TASK1
OFF
OFF
TASK2
ON
OFF
TASK3
OFF
ON
TASK4
ON
ON
Name
Description
BINARY_SEL input
This selects which task's data is output as binary.
Specify the task number in combinations of BINARY_SEL1 and 2.
It is only enabled in RUN mode.
Task Number
BINARY_SEL1
BINARY_SEL2
TASK1
OFF
OFF
TASK2
ON
OFF
TASK3
OFF
ON
TASK4
ON
ON