Parallel I/O connection
158
ZW User's Manual
Hold (auto peak/auto bottom/auto peak-to-peak)
Explanation of operations
(1) The peak value is updated and the judgment results and binary data are output.
(2) After the judgment result and binary data output, the analog output is updated.
(3) After the judgment result and binary data output, the GATE output is turned ON.
(4) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(5) The RESET input is turned ON. During the RESET input minimum time, if the RESET input is turned ON,
the measured value is reset.
(6) The judgment results and binary data are reset. The BUSY output is turned OFF.
(7) After the judgment results and binary data are reset, the analog output is reset.
(8) After the judgment result and binary data output, the GATE output is turned ON.
(9) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(10) The RESET input is turned OFF.
(11) The BUSY output is turned ON.
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
value
*
, sampling is not executed. If sampling has been started, it is stopped. The output value is as follows.
• Hold the clamp value.
• If the previous hold value is not the clamp value, the GATE signal is output.
• The BUSY signal is turned OFF.
To start and continue sampling even if a sampling value is an abnormal value or an undetermined value, set "KEEP"
as the non-measurement setting.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
Item
Min.
Max.
T3
Response time of analog output
0.1 ms
T4
GATE signal rise time
0.2 ms
T5
GATE signal output time
Setting value
(0.1 to 100.0 ms)
Setting value
(0.1 to 100.0 ms)
T6
TIMING input/RESET input minimum time
3 ms+T0
T7
Input response time
2 ms+T0
3 ms+T0×2
(1) (2)
T6
T3
T4
(3)
T5
(4)
(5)
T7
(6)(7) (
8
)
O
N
OFF
O
N
OFF
O
N
OFF
T3
T4
T5
(9) (10)
(11)
T7
J
u
dgment o
u
tp
u
t
(HIGH/PASS/LO
W
)
Binary o
u
tp
u
t
GATE o
u
tp
u
t
Analog o
u
tp
u
t
B
u
sy o
u
tp
u
t
RESET inp
u
t
Important
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......