Connecting Parallel I/O
272
ZW User's Manual
Setting Operation at Judgment Output
Setting Operation at Judgment Output p.144
As an example, the following explains the procedure for setting the timer type to "1 SHOT" and the timer
duration to "10ms".
Operating procedure
Steps
Key operation
Display
Description
1 to 3
For moving to "JUDGE", see steps 1 to 3 in p.271.
4
Select the judgment output setting item.
HYS: Hysteresis width
TIMER: Timer mode
In this example, press the
/
keys, select "TIMER" and press the
key.
5
Select the timer mode.
OFF: Not set
OFF.DLY: Off Delay
ONDLY: On Delay
1SHOT: One Shot
Select "1SHOT" as the judgment output type.
The current setting value is displayed on the sub-display.
Press the
/
keys to enter the editing mode, and the sub-display
blinks.
Select "1SHOT" and press the
key.
6
Set the timer duration.
The current setting value is displayed on the sub-display.
Press
key to enter the editing mode, and the sub-display blinks.
To edit numerical values, use the
/
/
/
keys.
In this example, input "10", then press the
key.
7
Press and hold the
key for two seconds to enter the RUN mode.