Setting Measurement Items
82
ZW User's Manual
Performing Calculations
Perform calculations using the results calculated by the tasks. The calculation formula is mX+nY+K.
Explorer pane
: [Bank] | [(Bank Data Name)] (double click)
Edit pane
: [Task Settings] icon (
)
Task Settings window : [Measurement mode] - [Calculation]
Item
Setting item
Setting value
Description
Calculation
Parameter X
OFF (default value)/TASK1 to TASK4
The task to be calculated can be switched.
Parameter Y
OFF (default value)/TASK1 to TASK4
The task to be calculated can be switched.
Parameter K
-999.999999 to 999.999999
(default value: 0)
Set the offset value.
Parameter m
-0.0 to 10.0 (Default value: 0)
Set the coefficient value.
Parameter n
-0.0 to 10.0 (Default value: 0)
Set the coefficient value.
1
Select the task to be calculated from
[Parameter X] and [Parameter Y].
2
Select the offset value from [Parameter K].
3
Select the coefficient from [Parameter m]
and [Parameter n].
Performing Calculations can also be set by the operating keys on the Sensor Controller.