Setting Measurement Items
ZW User's Manual
233
Senso
r con
trol
ler ope
ra
ti
ons
9
Calculating
As an example, here is an explanation of the output of the calculation result below.
(Example)
When calculating the amount of convexity and concavity on the object surface from the difference between the
average value and the peaks and outputting this to TASK3
TASK1: Surface peak hold
TASK2: Surface average hold
TASK3: TASK1 - TASK2 setting
• PARAMETER K: 0
• PARAMETER m: 1
• PARAMETER n: -1
• PARAMETERX: TASK1
• PARAMETERY: TASK2
Operating procedure
4-1
Press the
key to return to the previous menu.
4-2
Select "SUR2."
Press the
/
keys to select "END" and press the
key.
4-3
Select the measurement surface.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
In this example, select "EDGE2" and press the
key.
5
Scaling setting
6
Press the
key for two seconds to enter the RUN mode.
Steps
Key operation
Display
Description
1
Press and hold the
key for two seconds to enter the FUN
mode.
2
Press the
/
key to select MEAS, then press the
key.
Steps
Key operation
Display
Description
Summary of Contents for ZW-C1*T
Page 70: ...Operating with Sensor Controller 68 ZW User s Manual MEMO ...
Page 116: ...Setting the System 114 ZW User s Manual MEMO ...
Page 134: ...Controll input signal with PC tool 132 ZW User s Manual MEMO ...
Page 209: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 208 8 2 Troubleshooting 210 ...
Page 319: ...Index ZW User s Manual 317 Index 11 ...
Page 321: ......