Reflective Sensor Heads: FUN Mode Functions
Section 3-5
61
3-5-5
Timer
n
Timer Time
The time set for the timer is the delay time for the ON-delay timer, the delay
time for the OFF-delay timer, or the pulse width for the one-shot timer. Set
the time according to the requirements of the control system (e.g., PLC).
The timer time can be set to between 0 and 5,999 ms.
n
Timer Disable
If the timer is disabled, judgement outputs will be made immediately and
the output response time will be determined by the number of samples to
average.
n
OFF-delay Timer
When the measured value changes from HIGH to PASS or from LOW to
PASS, turning OFF the PASS output is delayed for the timer time.
n
ON-delay Timer
When the measured value changes from HIGH to PASS or from LOW to
PASS, turning ON the PASS output is delayed for the timer time.
n
One-shot Timer
When the measured value changes from HIGH to PASS or from LOW to
PASS, the PASS output is turn ON with a pulse width equivalent to the
timer time.
When PASS output pulses overlap, the latter pulse has priority. Therefore,
overlapping pulses might sometimes become a single pulse rather than
separate pulses.
Note:
Neither the HIGH nor the LOW output are output when the one-shot timer
is selected.
Refer to
4-5-6 FUN Mode Status Transitions
.
Summary of Contents for ZX Series
Page 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Page 2: ......
Page 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Page 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Page 160: ...FUN Function Mode Section 4 5 140 Memo ...
Page 166: ...Setting Problems Section 5 2 146 Memo ...
Page 186: ...Dimensions Section 6 2 166 Memo ...
Page 187: ......
Page 188: ...Z157 E1 01B ...