Reflective Sensor Heads: FUN Mode Functions
Section 3-5
67
Examples: Monitor Focus 2
Examples: Monitor Focus 3, Enabling Differentiation
4
4
60 80 120 140
60 70 120 140
Sensor display value
(mm)
Sensor display value
(mm)
Sensor display value
(mm)
60
140
For these settings:
For these settings:
4
−
4
−
4
Linear output voltage
Linear output voltage
Linear output
voltage
(V)
(V)
(V)
80 mm:
−
4 V
120 mm: 4 V
70 mm: 3 V
120 mm:
−
2 V
3
−
2
−
4
20
20
18
12
−
40
0 +20 +40
Linear output
current
(mA)
Linear output
current
(mA)
4
4
Sensor display value
(mm)
Sensor display value
(mm)
−
40
0
+40
For this setting:
12
20 mm: 18 mA