Reflective Sensor Heads: FUN Mode Functions
Section 3-5
68
3-5-9
Intensity Mode
The Intensity Mode can be selected either when using distance values for
display and output values or when using the received intensity (light level).
When the Intensity Mode is entered, the following are changed: Threshold
values (HIGH and LOW), hysteresis (hysteresis width), self-trigger level,
monitor focus function values, and the data for the received amount.
Note:
Set the gain switch to
when using Intensity Mode.
3-5-10 Differentiation Function
The differentiation function is used to convert variations in measured val-
ues into output values. Use it for measurements that monitor changes in
measured values, such as counting the number of sheets.
When the Differentiation Mode is enabled, the number of cycles (measure-
ment periods) to be compared can be set. (1 cycle: 150
μ
s )
Example: Measured Values and Differentiation Values
The variation in the measured values indicates the difference
between the previous and current measured values. This value will
decrease when the number of samples to average is increased.
Measured value
Only the measured values for " " are compared.
Number of samples
to average = 1
For 10 cycles
10 cycles
Differentiation value
Time
Time
Differentiation value changes
because of the difference
in the measured values.
Differentiation value changes
because of the difference
in the measured values.
Differentiation value is zero
because there is no difference
in the measured values.
Example:
(Note: Default
setting =
5,000 cycles)
POINT
Summary of Contents for ZX Series
Page 1: ...Cat No Z157 E1 01B OPERATION MANUAL ZX Series Smart Sensors ...
Page 2: ......
Page 3: ...Smart Sensors ZX Series Operation Manual Cat No Z157 E1 01B OMRON Corporation ...
Page 48: ...OutlineofFunctions Section 2 5 28 Memo ...
Page 160: ...FUN Function Mode Section 4 5 140 Memo ...
Page 166: ...Setting Problems Section 5 2 146 Memo ...
Page 186: ...Dimensions Section 6 2 166 Memo ...
Page 187: ......
Page 188: ...Z157 E1 01B ...