ZX-T
Operation Manual
Section 4
MAIN APPLICATIONS AND SETTING METHODS
Adjusting the Detection Position
Set a reference sample with a known thickness (T) between the Sensor Heads.
With the reference sample in place, adjust the Sensor Heads until the respective Ampli-
fier Units display as close to zero as possible.
Measurement distance, p. 119
Setting Expressions
Switch the CH2 Amplifier Unit to FUN mode and set 2-sensor operation (CALC) to
[A + B].
Refer to
Section 5 Detailed Settings
for details on operation.
Calculating Measured Values, p. 90
T
(mm)
POWER
ENABLE
ZERO
(mm)
POWER
ENABLE
ZERO
Rated measurement distance
Rated measurement distance
FUN
CH1=B
CH2=A