Zero Reset
103
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
• If zero reset memory is set to ON, the zero reset level will be written in the Amplifier Unit's
non-volatile memory (EEPROM) each time a zero reset is executed.
The EEPROM can be written a maximum of 100,000 times. Writing the zero reset level for
each measurement can, therefore, use up the life of the memory and lead to malfunctions.
3
Display setting at zero reset
4
Return to RUN mode
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
.
Press the button to enable
setting of values at a reset.
Set any value.
Press the
button to move
the digit, press the button to
change the numeric value, and
set the offset level.
* If the button is pressed
when the cursor is at the
right-most digit or the
button is pressed when the
cursor is at the left-most digit,
the setting will be canceled.
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
RUN mode.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Important
Set the zero reset memory function to set the
reference value to any numeric value.
Press to display
.
Default value: 0.000
Press to set.
[Change numeric value]
[Move digit]
Hold down for
3 seconds
Out