External Input for Bank, Timing Input, Reset Input
119
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
3
Return to RUN mode
Procedure for executing external input
Each of the functions is executed when signals are input using the external input wire in
table 1 below.
Timing input, reset input and bank switching are executed by a signal input of 4 ms or
more. While the signal in table 2 below is being input, measurement is performed based
on the settings of the specified bank.
When connecting two or more Amplifier Units, use the CH1 Amplifier Unit for bank
switching. The banks of the Amplifier Units of CH2 and later are switched together with
CH1.
Table 1 External Input Wiring
Table 2 Bank Signal Switching Wiring
Note:
Bank signal switching is enabled only in the RUN mode.
Select the
desired value.
Press the button to select the
external input terminal.
timing input/reset input
Bank switching
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
RUN mode.
Amplifier Unit
Connector
Cable Color
Setting
Purple
Red
Timing input
Reset input
BANK input 0
BANK input 1
BANK Input 0
(purple)
BANK Input 1
(red)
BANK 0
OFF
OFF
BANK 1
ON
OFF
BANK 2
OFF
ON
BANK 3
ON
ON
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press to select
Hold down for
3 seconds
Out